Combining the timeless grandeur of natural stone masonry with the structural agility of advanced alkali-resistant (AR) glassfibre composites.
Akvira Advanced Systems coordinates custom architectural GRC rainscreen cladding panels, complex parametric facades, intricate jali screens, and historic preservation mouldings conforming to GRCA and PCI standards.
Compared to precast concrete, reducing building foundation loads.
Zero flame spread, compliant with high-rise building fire codes.
High zirconia alkali-resistant glass ensures permanent durability.
Complex double-curved geometries and customized textures.
Manufactured using automated spray-premix technology with high-grade white portland cement, silica sand, and AR-glass rovings.
Large-format architectural facade panels engineered for rear-ventilated facade systems. Lightweight panels (typically 12mm to 18mm skin thickness) supported by internal stainless steel or galvanized steel sub-frames and adjustable cavity brackets.
Architectural Rainscreen
Sub-Frame Economy: Dramatic reduction in dead load allows for lighter perimeter structural steel and foundation sizing.
Weather Resistance: Hydrophobic silane-siloxane impregnations prevent efflorescence and atmospheric staining.
Perforated geometric solar screens engineered to reduce direct solar heat gain while preserving natural daylighting and ventilation. Highly popular in modern institutional buildings, airports, and heritage architecture.
Perforated GRC Jali
CNC Mold Tooling: Precision multi-axis CNC routed rubber and polyurethane molds ensure sub-millimeter lattice accuracy.
Classical and neo-classical architectural ornamentation reproduced with flawless surface finish and exact profiles. From intricate cornice bands and column wraps to monumental structural domes.
Mouldings & Column Casings
Direct hollow replacement for heavy carved sandstone or cast stone that poses safety and structural overloading challenges.
Test values measured according to BS EN 1170 series and GRCA specification for premix and sprayed GRC.
| Property Description | Test Standard | Sprayed GRC Grade 18P | Premix GRC Grade 10P |
|---|---|---|---|
| Limit of Proportionality (LOP - Flexural) | BS EN 1170-5 | 7 - 11 MPa | 5 - 8 MPa |
| Modulus of Rupture (MOR - Flexural) | BS EN 1170-5 | 18 - 30 MPa | 10 - 15 MPa |
| Compressive Strength | BS EN 1170-6 | 50 - 80 MPa | 40 - 60 MPa |
| AR Glass Fibre Content (% by weight) | BS EN 1170-2 | 4.5% - 5.5% | 2.5% - 3.5% |
| Density (Dry) | BS EN 1170-6 | 1900 - 2100 kg/m³ | 1800 - 2000 kg/m³ |
| Fire Performance Rating | BS 476 Part 4 / EN 13501-1 | Class A1 Non-Combustible | Class A1 Non-Combustible |
Connect with our facade engineers and tooling specialists. Share facade drawings, module schedules, surface finishes, or CAD files for technical estimation.